A novel method for Co (Ⅱ) and Cu (Ⅱ) analysis by capillary electrophoresis with chemiluminescence detection
摘要:
Based on the fact that some metal ions can catalyze the chemiluminescence (CL) reaction of luminol with K3Fe (CN) 6, a novel capillary electrophoresis CL method was developed for the determination of Co (Ⅱ) and Cu (Ⅱ). The separation was carried out with a 10 mmol/L sodium acetate solution containing 0.8 mmol/L luminol and 2.0 mmol/L α-HIBA (adjusted to pH 4.8 by Hac solution). The post-capillary reagent was 2.0 mmol/L K3Fe (CN) 6which was adjusted to pH 13.0 by NaOH solution. Under the optimum conditions, the detection limits (S/N=3) for Co (Ⅱ) and Cu (Ⅱ) were 7.5×10-11 mol/L and 7.5×10-9 mol/L, with the linear range of 7.5×10-9 mol/L to 1.0×10-6 mol/L and 7.5×10-8 mol/L to 5.0×10-5 mol/L, respectively.
-
关键词:
- Capillary electrophoresis
- / Chemiluminescence
- / Co (Ⅱ)
- / Cu (Ⅱ)
English
A novel method for Co (Ⅱ) and Cu (Ⅱ) analysis by capillary electrophoresis with chemiluminescence detection
Abstract:
Based on the fact that some metal ions can catalyze the chemiluminescence (CL) reaction of luminol with K3Fe (CN) 6, a novel capillary electrophoresis CL method was developed for the determination of Co (Ⅱ) and Cu (Ⅱ). The separation was carried out with a 10 mmol/L sodium acetate solution containing 0.8 mmol/L luminol and 2.0 mmol/L α-HIBA (adjusted to pH 4.8 by Hac solution). The post-capillary reagent was 2.0 mmol/L K3Fe (CN) 6which was adjusted to pH 13.0 by NaOH solution. Under the optimum conditions, the detection limits (S/N=3) for Co (Ⅱ) and Cu (Ⅱ) were 7.5×10-11 mol/L and 7.5×10-9 mol/L, with the linear range of 7.5×10-9 mol/L to 1.0×10-6 mol/L and 7.5×10-8 mol/L to 5.0×10-5 mol/L, respectively.
-
Key words:
- Capillary electrophoresis
- / Chemiluminescence
- / Co (Ⅱ)
- / Cu (Ⅱ)