引用本文:
Jun Ping Xiao, Qing Xiang Zhou, Xiao Ke Tian, Hua Hua Bai, Xian Fa Su. Determination of aniline in environmental water samples by alternating-current oscillopolarographic titration[J]. Chinese Chemical Letters,
2007, 18(6): 730-733.
doi:
10.1016/j.cclet.2007.04.030
Citation: Jun Ping Xiao, Qing Xiang Zhou, Xiao Ke Tian, Hua Hua Bai, Xian Fa Su. Determination of aniline in environmental water samples by alternating-current oscillopolarographic titration[J]. Chinese Chemical Letters, 2007, 18(6): 730-733. doi: 10.1016/j.cclet.2007.04.030

Citation: Jun Ping Xiao, Qing Xiang Zhou, Xiao Ke Tian, Hua Hua Bai, Xian Fa Su. Determination of aniline in environmental water samples by alternating-current oscillopolarographic titration[J]. Chinese Chemical Letters, 2007, 18(6): 730-733. doi: 10.1016/j.cclet.2007.04.030

Determination of aniline in environmental water samples by alternating-current oscillopolarographic titration
摘要:
A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper.Several factors including the kind, concentration, and volume of acid, the dosage of potassium bromide, the temperature and concentration of concomitant substances were investigated in detail.The experimental results indicated that this method was simple, rapid, and sensitive.The linear range was 8.367×10-4 to 2.789×10-2 mol L-1, the relative standard deviation (R.S.D.) was lower than 0.96%, and the spiked recoveries of aniline in environmental water samples were in the range of 99.4-106.9% under the optimal conditions.The results indicated that the present method could be used as an alternative method for aniline determination in realworld water samples.
English
Determination of aniline in environmental water samples by alternating-current oscillopolarographic titration
Abstract:
A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper.Several factors including the kind, concentration, and volume of acid, the dosage of potassium bromide, the temperature and concentration of concomitant substances were investigated in detail.The experimental results indicated that this method was simple, rapid, and sensitive.The linear range was 8.367×10-4 to 2.789×10-2 mol L-1, the relative standard deviation (R.S.D.) was lower than 0.96%, and the spiked recoveries of aniline in environmental water samples were in the range of 99.4-106.9% under the optimal conditions.The results indicated that the present method could be used as an alternative method for aniline determination in realworld water samples.

计量
- PDF下载量: 0
- 文章访问数: 636