引用本文:
Mohammad A. Khalilzadeh, Hassan Karimi-Maleh, Azra Amiri, Fathali Gholami, Robabeh Motaghed mazhabi. Determination of captopril in patient human urine using ferrocenemonocarboxylic acid modified carbon nanotubes paste electrode[J]. Chinese Chemical Letters,
2010, 21(12): 1467-1470.
doi:
10.1016/j.cclet.2010.06.020
Citation: Mohammad A. Khalilzadeh, Hassan Karimi-Maleh, Azra Amiri, Fathali Gholami, Robabeh Motaghed mazhabi. Determination of captopril in patient human urine using ferrocenemonocarboxylic acid modified carbon nanotubes paste electrode[J]. Chinese Chemical Letters, 2010, 21(12): 1467-1470. doi: 10.1016/j.cclet.2010.06.020
Citation: Mohammad A. Khalilzadeh, Hassan Karimi-Maleh, Azra Amiri, Fathali Gholami, Robabeh Motaghed mazhabi. Determination of captopril in patient human urine using ferrocenemonocarboxylic acid modified carbon nanotubes paste electrode[J]. Chinese Chemical Letters, 2010, 21(12): 1467-1470. doi: 10.1016/j.cclet.2010.06.020
Determination of captopril in patient human urine using ferrocenemonocarboxylic acid modified carbon nanotubes paste electrode
摘要:
In this work. we describe a new strategy for the electrochemical determination of captopril (CA) using ferrocenemonocarboxylic acid as a mediator and muhiwall carbon nanotubes as sensors in aqueous solution at pH 7.0. The diffusion coefficient (D), and the kinetic parameters such as electron transfer coefficient (α), and heterogeneous rate constant (kh), for CA were also determined using electrochemical approaches. Under the optimized conditions, the electrocatalytic oxidation peak current of captopril showed. two linear dynamic ranges with a detection limit of 0.3×10-6 mol L-1 captopril. The linear calibration range was 0.8×10-6 to 65×10-6 mol L-1 using cyclic voltammetry. Finally, this modified electrode was also examined as a selective, simple and precise new electrochemical sensor for the determination of captopril in real samples such as drug and patient human urine.
English
Determination of captopril in patient human urine using ferrocenemonocarboxylic acid modified carbon nanotubes paste electrode
Abstract:
In this work. we describe a new strategy for the electrochemical determination of captopril (CA) using ferrocenemonocarboxylic acid as a mediator and muhiwall carbon nanotubes as sensors in aqueous solution at pH 7.0. The diffusion coefficient (D), and the kinetic parameters such as electron transfer coefficient (α), and heterogeneous rate constant (kh), for CA were also determined using electrochemical approaches. Under the optimized conditions, the electrocatalytic oxidation peak current of captopril showed. two linear dynamic ranges with a detection limit of 0.3×10-6 mol L-1 captopril. The linear calibration range was 0.8×10-6 to 65×10-6 mol L-1 using cyclic voltammetry. Finally, this modified electrode was also examined as a selective, simple and precise new electrochemical sensor for the determination of captopril in real samples such as drug and patient human urine.
扫一扫看文章
计量
- PDF下载量: 0
- 文章访问数: 1659
- HTML全文浏览量: 40

下载: