Citation:
CHEN Wei, CHEN Yu-Quan. Fabrication of Flexible Continuous Glucose Monitoring Sensor by Non-Patterning Method[J]. Chinese Journal of Analytical Chemistry,
;2016, 44(4): 654-659.
doi:
10.11895/j.issn.0253-3820.150542
-
A tight gold layer was electroless plated on polyimide film coated with polydopamine. A polyurethane coated flexible glucose sensor was developed based on this two side gold layer structure, wherein the platinum black plating side was used as reference-counter electrode and another side that was successively modified by platinum black layer, Nafion/carbon nanotube(CNT) layer and glucose oxidase(Gox) layer as working electrode. The morphology of each layer and its influence on glucose sensing performance were investigated. The glucose biosensor showed a linear range from 2.0 to 32.0 mmol/L and the sensitivity was 25μA·(mmol/L)-1·cm-2 at low potential of 0.3 V, with a detection limit of 0.05 mmol/L(S/N=3). The biosensor could avoid the commonly coexisted interference and exhibited high stability in the continuous subcutaneous glucose monitoring.
-
-
-
[1]
1 Mastrototaro J. J. Pediatr. Endocr Met., 1999, 123:751-758
-
[2]
2 Hoss U, Jeddi I, Schulz M, Budiman E, Bhogal C, McGarraugh G. Diabetes Technol., 2010, 12(8):591-597
-
[3]
3 Heller A, Feldman B. Accounts Chem. Res., 2010, 43(7):963-973
-
[4]
4 Koschwanez H E, Yap F Y, Klitzman B, Reichert W M. J. Biomed. Mater. Res. A, 2008, 87A(3):792-807
-
[5]
5 Shults M C, Rhodes R K, Updike S J. Brauker J H. U.S. Patent, US07901354, 2011
-
[6]
6 Wilson G S, Zhang Y, Reach G, Moattisirat D, Poitout V, Thevenot D R, Lemonnier F, Klein J C. Clin. Chem., 1992, 38(9):1613-1617
-
[7]
7 Lu Z, Xiao J, Wang Y, Meng M. J. Colloid Interf. Sci., 2015, 452:8-14
-
[8]
8 Horiuchi S, Nakao Y. Surf. Coat. Tech., 2010, 204(23):3811-3817
-
[9]
9 Ball V, Del Frari D, Toniazzo V, Ruch D. J. Colloid Interf. Sci., 2012, 386:366-372
-
[10]
10 Heli H, Sattarahmady N, Vais R D, Mehdizadeh A R. Sens. Actuator B, 2014, 192:310-316
-
[11]
11 Jung-Chuan C, Jhang C, Yi-Hung L, Lin J, Chen R, Hsueh-Tao C. IEEE T. Semiconduct. M., 2014, 27(4):523-529
-
[12]
12 Guo M Q, Hong H S, Tang X N, Fang H D, Xu X H. Electrochim. Acta, 2012, 63:1-8
-
[13]
13 Park S, Boo H, Chung T D. Anal. Chim. Acta, 2006, 556(1):46-57
-
[1]
-
-
-
[1]
Qiaoqiao BAI , Anqi ZHOU , Xiaowei LI , Tang LIU , Song LIU . Construction of pressure-temperature dual-functional flexible sensors and applications in biomedicine. Chinese Journal of Inorganic Chemistry, 2024, 40(12): 2259-2274. doi: 10.11862/CJIC.20240128
-
[2]
Xingchao Zhao , Xiaoming Li , Ming Liu , Zijin Zhao , Kaixuan Yang , Pengtian Liu , Haolan Zhang , Jintai Li , Xiaoling Ma , Qi Yao , Yanming Sun , Fujun Zhang . 倍增型全聚合物光电探测器及其在光电容积描记传感器上的应用. Acta Physico-Chimica Sinica, 2025, 41(1): 2311021-. doi: 10.3866/PKU.WHXB202311021
-
[3]
Jiarong Feng , Yejie Duan , Chu Chu , Dezhen Xie , Qiu'e Cao , Peng Liu . Preparation and Application of a Streptomycin Molecularly Imprinted Electrochemical Sensor: A Suggested Comprehensive Analytical Chemical Experiment. University Chemistry, 2024, 39(8): 295-305. doi: 10.3866/PKU.DXHX202401016
-
[4]
Meiqing Yang , Lu Wang , Haozi Lu , Yaocheng Yang , Song Liu . Recent Advances of Functional Nanomaterials for Screen-Printed Photoelectrochemical Biosensors. Acta Physico-Chimica Sinica, 2025, 41(2): 100018-. doi: 10.3866/PKU.WHXB202310046
-
[5]
Tengjiao Wang , Tian Cheng , Rongjun Liu , Zeyi Wang , Yuxuan Qiao , An Wang , Peng Li . Conductive Hydrogel-based Flexible Electronic System: Innovative Experimental Design in Flexible Electronics. University Chemistry, 2024, 39(4): 286-295. doi: 10.3866/PKU.DXHX202309094
-
[6]
Tiantian MA , Sumei LI , Chengyu ZHANG , Lu XU , Yiyan BAI , Yunlong FU , Wenjuan JI , Haiying YANG . Methyl-functionalized Cd-based metal-organic framework for highly sensitive electrochemical sensing of dopamine. Chinese Journal of Inorganic Chemistry, 2024, 40(4): 725-735. doi: 10.11862/CJIC.20230351
-
[7]
Hexing SONG , Zan SUN . Synthesis, crystal structure, Hirshfeld surface analysis, and fluorescent sensing for Fe3+ of an Mn(Ⅱ) complex based on 1-naphthalic acid. Chinese Journal of Inorganic Chemistry, 2025, 41(5): 885-892. doi: 10.11862/CJIC.20240402
-
[8]
Lu XU , Chengyu ZHANG , Wenjuan JI , Haiying YANG , Yunlong FU . Zinc metal-organic framework with high-density free carboxyl oxygen functionalized pore walls for targeted electrochemical sensing of paracetamol. Chinese Journal of Inorganic Chemistry, 2024, 40(5): 907-918. doi: 10.11862/CJIC.20230431
-
[9]
Jing SU , Bingrong LI , Yiyan BAI , Wenjuan JI , Haiying YANG , Zhefeng Fan . Highly sensitive electrochemical dopamine sensor based on a highly stable In-based metal-organic framework with amino-enriched pores. Chinese Journal of Inorganic Chemistry, 2024, 40(7): 1337-1346. doi: 10.11862/CJIC.20230414
-
[10]
Jun LUO , Baoshu LIU , Yunchang ZHANG , Bingkai WANG , Beibei GUO , Lan SHE , Tianheng CHEN . Europium(Ⅲ) metal-organic framework as a fluorescent probe for selectively and sensitively sensing Pb2+ in aqueous solution. Chinese Journal of Inorganic Chemistry, 2024, 40(12): 2438-2444. doi: 10.11862/CJIC.20240240
-
[11]
Wenjie SHI , Fan LU , Mengwei CHEN , Jin WANG , Yingfeng HAN . Synthesis and host-guest properties of imidazolium-functionalized zirconium metal-organic cage. Chinese Journal of Inorganic Chemistry, 2025, 41(1): 105-113. doi: 10.11862/CJIC.20240360
-
[12]
Fugui XI , Du LI , Zhourui YAN , Hui WANG , Junyu XIANG , Zhiyun DONG . Functionalized zirconium metal-organic frameworks for the removal of tetracycline from water. Chinese Journal of Inorganic Chemistry, 2025, 41(4): 683-694. doi: 10.11862/CJIC.20240291
-
[13]
Shiyang He , Dandan Chu , Zhixin Pang , Yuhang Du , Jiayi Wang , Yuhong Chen , Yumeng Su , Jianhua Qin , Xiangrong Pan , Zhan Zhou , Jingguo Li , Lufang Ma , Chaoliang Tan . 铂单原子功能化的二维Al-TCPP金属-有机框架纳米片用于增强光动力抗菌治疗. Acta Physico-Chimica Sinica, 2025, 41(5): 100046-. doi: 10.1016/j.actphy.2025.100046
-
[14]
Lina Guo , Ruizhe Li , Chuang Sun , Xiaoli Luo , Yiqiu Shi , Hong Yuan , Shuxin Ouyang , Tierui Zhang . 层状双金属氢氧化物的层间阴离子对衍生的Ni-Al2O3催化剂光热催化CO2甲烷化反应的影响. Acta Physico-Chimica Sinica, 2025, 41(1): 2309002-. doi: 10.3866/PKU.WHXB202309002
-
[15]
Lin Song , Dourong Wang , Biao Zhang . Innovative Experimental Design and Research on Preparing Flexible Perovskite Fluorescent Gels Using 3D Printing. University Chemistry, 2024, 39(7): 337-344. doi: 10.3866/PKU.DXHX202310107
-
[16]
Yuhang Zhang , Weiwei Zhao , Hongwei Liu , Junpeng Lü . 基于低维材料的自供电光电探测器研究进展. Acta Physico-Chimica Sinica, 2025, 41(3): 2310004-. doi: 10.3866/PKU.WHXB202310004
-
[17]
Yao Ma , Xin Zhao , Hongxu Chen , Wei Wei , Liang Shen . Progress and Perspective of Perovskite Thin Single Crystal Photodetectors. Acta Physico-Chimica Sinica, 2025, 41(4): 100030-. doi: 10.3866/PKU.WHXB202309045
-
[18]
Fang Niu , Rong Li , Qiaolan Zhang . Analysis of Gas-Solid Adsorption Behavior in Resistive Gas Sensing Process. University Chemistry, 2024, 39(8): 142-148. doi: 10.3866/PKU.DXHX202311102
-
[19]
Zhongxin YU , Wei SONG , Yang LIU , Yuxue DING , Fanhao MENG , Shuju WANG , Lixin YOU . Fluorescence sensing on chlortetracycline of a Zn-coordination polymer based on mixed ligands. Chinese Journal of Inorganic Chemistry, 2024, 40(12): 2415-2421. doi: 10.11862/CJIC.20240304
-
[20]
Hongsheng Tang , Yonghe Zhang , Dexiang Wang , Xiaohui Ning , Tianlong Zhang , Yan Li , Hua Li . A Wonderful Journey through the Kingdom of Hazardous Chemicals. University Chemistry, 2024, 39(9): 196-202. doi: 10.12461/PKU.DXHX202403098
-
[1]
Metrics
- PDF Downloads(2)
- Abstract views(327)
- HTML views(27)