
Citation: WU Na, SHEN Yuan, WANG Li, SONG Yong-Hai. On-Off Ratiometric Electrochemical Sensor for Ascorbic Acid Based on Three-dimensional Kenaf Stem Porous Carbon/Thinion Integrated Electrode[J]. Chinese Journal of Analytical Chemistry, 2020, 48(12): 1650-1657. doi: 10.19756/j.issn.0253-3820.201419

基于洋麻秆衍生的三维多孔碳/硫堇比率型抗坏血酸电化学传感器
English
On-Off Ratiometric Electrochemical Sensor for Ascorbic Acid Based on Three-dimensional Kenaf Stem Porous Carbon/Thinion Integrated Electrode
-
Key words:
- Porous carbon
- / Thionine
- / Ratiometric electrochemical sensor
- / Ascorbic acid
-
-
-
[1]
Hsieh Y C, Tsou P Y, Wang Y H, Chao C C T, Lee W C, Lee M G, Wu J Y, Chang S S, Chen P Y, Lee C C. J. Intensive Care Med.,2020,35(1):34-41
-
[2]
Kiani M E. U.S. Patent Application 10/226,576.2019-3-12
-
[3]
Piliponsky A M, Shubin N J, Lahiri A K, Truong P, Clauson M, Niino K, Tsuha A L, Nedospasov S A, Karasuyama H, Reber L L, Tsai M, Mukai K, Galli S J. Nat. Immunol.,2019,20(2):129-140
-
[4]
Blaszczak W, Barczak W, Masternak J, Kopczynski P, Zhitkovich A, Rubis B. Molecules,2019,24(3):453
-
[5]
Jothi L, Neogi S, Jaganathan S K, Nageswaran G. Biosens. Bioelectron.,2018,105:236-242
-
[6]
Jin P F, Xia L F, Li Z, Che N, Zou D, Hu X. J. Pharm. Biomed. Anal.,2012,70(11):151-157
-
[7]
Tunca A K, Ozaraz M. Int. J. Life Sci. Pharm. Res.,2019,9(4):45-60
-
[8]
Tsochatzis E, Papageorgiou M, Kalogiannis S. Foods,2019,8(10):514
-
[9]
Wawrzyniak R, Jasiewicz B. Food Chem.,2019,301:125264
-
[10]
Aresta A, Zambonin C. J. Pharm. Biomed. Anal.,2016,121:63-68
-
[11]
Maduraiveeran G, Sasidharan M, Ganesan V. Biosens. Bioelectron.,2018,103:113-129
-
[12]
JI Wen-Liang, ZHANG Mei-Ning, MAO Lan-Qun. Chinese J. Anal. Chem.,2019,47(10):1559-1571 纪文亮, 张美宁,毛兰群.分析化学,2019,47(10):1559-1571
-
[13]
Zhang L J, Wang G H, Wu D, Xiong C, Zheng L, Ding Y S, Lu H B, Zhang G B, Qiu L Z. Biosens. Bioelectron.,2018,100:235-241
-
[14]
Rizwan M, Elma S, Lim S A, Ahmed M U. Biosens. Bioelectron.,2018,107:211-217
-
[15]
Alam A U, Qin Y, Howlader M M R, HU N X, Deen M J. Sens. Actuators B,2018,254:896-909
-
[16]
LI Rui-Yi, CHU Hong-Xia,YU Min-Yi, LI Shu-Han, LI Zai-Jun. Chinese J.Anal.Chem.,2020,48(7):871-880 李瑞怡, 储红霞, 余敏仪, 李姝晗, 李在均.分析化学,2020,48(7):871-880
-
[17]
Alba P A, Adover J C, de la R R. ACS Sens.,2020,5(1):147-153
-
[18]
Bobulescu I A, Park S K, Xu L H R, Blanco F, Poindexter J, Adams-Huet B, Davidson T L, Sakhaee K, Maalouf N M, Moe O W. Clin. J. Am. Soc. Nephrol.,2019,14(3):411-420
-
[19]
Anuar N S, Basirun W J, Ladan M, Shalauddin M, Mehmood M S. Sens. Actuators B,2018,266:375-383
-
[20]
Zhou L, Hou H F, Wei H, Yao L N, Sun L, Yu P, Su B, Mao L Q. Anal. Chem.,2019,91(5):3645-3651
-
[21]
Wang X X, Liu G M, Qi Y X, Yuan Y, Gao J, Luo X L, Yang T. Anal. Chem.,2019,91(18):12006-12013
-
[22]
Song Y H, Xu M L, Gong C C, Shen Y, Wang L Y, Xie Y, Wang L. Sens. Actuators B,2018,257:792-799
-
[23]
Li Y R, Chang Y Y, Ma J, Wu Z Y, Yuan R, Chai Y Q. Anal. Chem.,2019,91(9):6127-6133
-
[24]
Li S, Tian Y. Electroanalysis,2018,30(6):1047-1053
-
[25]
Song Y H, Lu X P, Li Y, Guo Q H, Chen S L, Mao L Q, Hou H Q, Wang L. Anal. Chem.,2016,88(2):1371-1377
-
[26]
Han D X, Han T T, Shan C S, Ivaska A, Niu L. Electroanalysis,2010,22(17-18):2001-2008
-
[27]
Bao Y, Song J X, Mao Y, Han D X, Yang F, Niu L, Ivaska A. Electroanalysis,2011,23(4):878-884
-
[28]
Cai W H, Lai J W, Lai T, Xie H T, Ye J S. Sens. Actuators B,2016,224:225-232
-
[29]
Habibi B, Pournaghi-Azar M H. Electrochim. Acta,2010,55(19):5492-5498
-
[30]
Fernandes D M, Costa M, Pereira C, Bachiller B B, Rodriguez R I, Guerrero R A, Freire C. J. Colloid Interface Sci.,2014,432(20):207
-
[31]
Wang S Y, Zhang W, Zhong X, Chai Y Q, Yuan R. Anal. Methods,2015,7:1471-1477
-
[1]
-

计量
- PDF下载量: 5
- 文章访问数: 897
- HTML全文浏览量: 62