A simple fluorescent sensor for highly sensitive detection of UO22+

Huanhuan Ding Chenguang Li Hailing Zhang Na Lin Wen-Sheng Ren Shicheng Li Weidong Liu Zhonghua Xiong Binyuan Xia Chong-Chen Wang

Citation:  Huanhuan Ding, Chenguang Li, Hailing Zhang, Na Lin, Wen-Sheng Ren, Shicheng Li, Weidong Liu, Zhonghua Xiong, Binyuan Xia, Chong-Chen Wang. A simple fluorescent sensor for highly sensitive detection of UO22+[J]. Chinese Chemical Letters, 2023, 34(4): 107725. doi: 10.1016/j.cclet.2022.08.005 shu

A simple fluorescent sensor for highly sensitive detection of UO22+

English

  • Uranium is a toxic and radioactive nuclide, which is widely applied in civil and military nuclear fields [1, 2]. Human exposure to uranium has reported to result in a series of health problems, such as cancer, renal system ailments and genetic diseases [3, 4]. As the growing utilization of nuclear energy, especially the occurrence of undesirable nuclear accidents, uranium contamination is widely found in natural waters, such as river [5], groundwater [6] and ocean [7]. The pollution of uranium in environment water has become a social concern. Thus, it is of great significance to detect the concentration of uranium in aqueous environment.

    Uranium is usually associated with oxygen, forming various oxidation states (i.e. +2, +3, +4, +5, +6), and uranyl ion (UO22+) is the most stable chemical form in aqueous environment. Until now, routine methods for the trace level uranyl detection mainly include inductively coupled plasma mass spectrometry (ICP-MS) [8], inductively coupled plasma optical emission spectrometry (ICP-OES) [9], atomic emission spectroscopy (AES) [10] and surface-enhanced Raman scattering (SERS) [11]. Although these techniques are sensitive and reliable, they often require large and expensive equipments, complicated processing procedures, strict operations and relatively long analysis time, which restrict the on-site rapid detection of UO22+. Fluorescence analysis, with the advantages of easy operation, simple apparatus, excellent sensitivity and real-time monitoring, has been received increasing attention [12]. In recent years, some organic fluorescence sensors for detecting UO22+ have been reported [13, 14]. However, most of these sensors show low solubility in water and would suffer from suppressed emission or even complete fluorescence quenching in high water fractions, which limited their practical applications.

    Among the fluorescence analysis techniques, fluorescence organic molecules with aggregation-induced emission (AIE) property have been shown to be particularly valuable, as first reported by Zhang et al. [15]. Tetraphenylenthene (TPE) moiety has been reported as an excellent fluorophore for designing of AIE sensors. To date, a variety of TPE-based fluorescent sensors have been developed and utilized, such as for Th4+ [16], Cu2+ [15] and Hg2+ [17]. Wen et al. [18] and Lin et al. [19] developed two TPE-based fluorescent sensors, TPE-T and TPE-BSA, respectively. The two sensors monitored UO22+ with high water fractions, whereas the detection limit could not reach the levels of UO22+ in natural waters (0.31 µg/L for global rivers [20], and 3.3 µg/L for ocean [7]), approximatively nanomolar level. Therefore, to further improve the sensitivity is the key to achieve the determination of trace uranium in the environment.

    Amidoxime group (–C(NH2)=N-OH), which has been reported to be used for uranium extraction from seawater, is one of the best groups to adsorb UO22+ from aqueous solution and reveals strong affinity for UO22+ [13, 21, 22]. Herein, a novel and sensitive fluorescence sensor (TPE-A) is developed through a synthesis of tetraphenylenthene fluorophore with amidoxime group. It is demonstrated that this sensor system could greatly improve the fluorescence detection sensitivity reaching 4.7 × 10−9 mol/L, attributed to the promoted adsorption ability of amidoxime groups to UO22+. In addition, analytical application of the method for determination of UO22+ in FuJiang River samples was successfully conducted, which showed that TPE-A could be a sensitive and convenient fluorescent sensor for trace UO22+ detection.

    Details of TPE-A synthesis, characterization methods, spectroscopic and adsorption measurements are described in Supporting information.

    The AIE fluorescence characteristic of TPE-A was studied in H2O/THF (from 0 to 1, v/v) with various water volume fractions (fw). Fig. 1a shows the emission of TPE-A in various H2O/THF mixtures. When the water fraction increases from 0% to 80% (Fig. S5 in Supporting information), the fluorescence intensity at 444 nm remains almost unchanged. While the water content reaches 85%, the fluorescence intensity of TPE-A increases significantly, and gets to its climax when the water content reaches 90%. The fluorescence intensity of the mixture (fw = 90%) increases by 147-fold compared to the TPE-A in mixture (fw = 0%). TPE-A aggregates in aqueous solutions with high water fractions since it is soluble in THF and poorly soluble in water. In dispersed solution, the fluorophores emit almost no light caused by their rotation or twisting motions against each other with the solvent media transforms the photonic energy to thermal energy. Upon aggregate formation, the emission of TPE-A is induced or rejuvenated by the restriction of intramolecular motions (RIM) [23, 24]. When fw increases from 90% to 100%, the fluorescence intensity decreases, because TPE-A may agglomerate rapidly to form amorphous materials with decreased emission [25].

    Figure 1

    Figure 1.  (a) Fluorescence spectra of TPE-A (10 µmol/L) in H2O/THF mixtures with fw ranging from 0% to 100%. Dynamic light scattering results of (b) TPE-A (10 µmol/L) in H2O/THF (90/10, v/v) mixture, (c) TPE-A (10 µmol/L) in H2O/THF (85/15, v/v) mixture, and (d) TPE-A (10 µmol/L) with UO22+ (0.5 µmol/L) in the H2O/THF (85/15, v/v) mixture.

    To confirm the presence of aggregates, particle size distribution analyses (Figs. 1bd) were performed on dynamic light scattering (DLS) experiments. As shown in Figs. 1b and c, nanoparticles with an average size of ca. 1822.1 nm (fw = 90%) and 137.6 nm (fw = 85%) are observed, respectively, which suggests the formation of fluorescent aggregates of TPE-A. Moreover, the stability test of the fluorescent sensor was conducted to evaluate the performance. It is observed that the fluorescence intensity of the mixture (fw = 85%) at 444 nm stays almost constant in 600 s, while the fluorescence intensity of the mixture (fw = 90%) fluctuates continually and enhances dramatically at 323 s (Fig. S6 in Supporting information), indicating the mixture (fw = 90%) is unstable. Then, flocculent precipitation is observed after 10 min (Fig. S7 in Supporting information). Considering the stability, the water fraction (fw = 85%) would be chosen as the optimum condition for detecting experiments of UO22+.

    The fluorescence properties of the sensor are affected by the pH. As shown in Fig. 2a, the effect of pH value was studied in the range of 4.0 to 9.0. TPE-A exhibits strong fluorescence intensity in the absence of UO22+ at different pH values (from 4.0 to 9.0). After addition of 0.5 µmol/L UO22+, the emission of TPE-A (10 µmol/L) could be quenched remarkably under acidic and neutral conditions, while quenched only 56.3% at pH 8.0 and 23.6% at pH 9.0 (Table S1 in Supporting information), which may be due to some uranyl exists in the form of anions in alkaline conditions (Fig. S8a in Supporting information). Considering the rigorous operation under acidic condition, neutral condition (pH 7.0) is chosen as the optimal experimental condition.

    Figure 2

    Figure 2.  (a) Fluorescence intensity of TPE-A (10 µmol/L) and TPE-A (10 µmol/L) + UO22+ (0.5 µmol/L) at 444 nm in H2O/THF (85/15, v/v) solution at different pH. (b) The response time curve of TPE-A (10 µmol/L) to uranyl ions (0.5 µmol/L) at 444 nm in H2O/THF (85/15, v/v) mixture at pH 7.0. (c) Fluorescence spectra of TPE-A (10 µmol/L) in the presence of different concentrations (0-0.5 µmol/L) in the H2O/THF (85/15, v/v) solution at pH 7.0. (d) The linear plot and relationship of (F0-F)/F0 versus the concentrations of UO22+ (0.05-0.45 µmol/L).

    In order to study the response time of TPE-A to UO22+, the fluorescence intensity within 8 min was recorded (Fig. 2b). It can be seen that the fluorescence intensity at 444 nm stays almost constant after 4 min. The short reaction time of the TPE-A toward UO22+ might be related to the strong coordination of amidoxime group.

    In order to estimate the potential of TPE-A as a sensor for the UO22+ detection, UO22+ was gradually added to H2O/THF (fw = 85%) mixture in titration experiment. Fluorescence responses of TPE-A to UO22+ were then recorded. Fig. 2c shows the emission intensity of TPE-A in the presence of UO22+. Notably, fluorescence intensity of the mixture decreases gradually with the concentration of UO22+ increases. Fig. S9 (Supporting information) shows the relationship between fluorescence intensity at 444 nm and the concentration of UO22+. Moreover, the fluorescence quenching efficiency ((F0-F)/F0, F and F0 are the emission intensities at 444 nm in the presence and absence of the UO22+, respectively) exhibits a good linear relationship with the concentration of UO22+ in the range of 0.05 µmol/L to 0.45 µmol/L (Fig. 2d). The linear equation is Y = 1.784X-0.00826 (R2 = 0.9988) with Y as the fluorescence quenching efficiency, X as the UO22+ concentration. The minimum detection limit is 4.7 × 10−9 mol/L calculated according to LOD = 3σ/k, where σ is the standard deviation of the blank measurement, and k is the slope of linear equation. The results show that the LOD is below the limit for uranium in drinking water (30 µg/L, ca. 1.1 × 10−7 mol/L) defined by the WHO, suggesting that TPE-A could be used as a novel fluorescence sensor for the determination of trace UO22+ in environmental samples.

    The existence of UO22+ results in a gradual quenching of TPE-A emission. The Stern-Volmer plot (F0/F = 1 + KsvQ) was determined to evaluate the fluorescence quenching efficiency of TPE-A upon UO22+, where F0 and F are the fluorescence intensities in the absence and presence of UO22+, Q is the concentration of UO22+, and Ksv is the Stern-Volmer quenching constant, and the bigger Ksv, the better quenching efficiency. As shown in Fig. S10 (Supporting information), the plot curves upward with the increase of UO22+ concentration, indicating that TPE-A has a high quenching efficiency. The inset in Fig. S10 shows that a linear Stern-Volmer plot is obtained with a large Ksv of 2.76 × 106 L/mol at low concentration of UO22+, indicating that the TPE-A has high sensitivity for uranyl ion.

    Metal ions in environmental waters could interfere with the detection of UO22+. Various common metal ions (Be2+, Ca2+, Fe3+, K+, Li+, Mg2+, Na+, W6+, Zn2+) were selected as potential interference substances. Fluorescence quenching degrees (1-F/F0) were performed in this study. As illustrated in Fig. 3a, most metal ions only cause ignorable fluorescence changes of TPE-A (by about 5%). It is noticed that Mg2+ quenches the fluorescence by about 9%. On the contrast, the addition of UO22+ results in almost complete fluorescence quenching of TPE-A (> 99%), much higher than those of common metal ions (Table S2 in Supporting information). To further evaluate the influence of metal ions to the detection of UO22+, competition experiments were also performed. As showed in Fig. 3b and Table S2 (Supporting information), the fluorescence intensity in the presence of UO22+ mixed with common ions is almost same with that of UO22+ alone, suggesting that the sensor has strong binding capacity among the tested metal ions. The interference and competition experiments of anions and humic acid (HA) as natural organic matter were also conducted, respectively. Fig. S11 and Table S2 (Supporting information) show the fluorescence intensity in the presence of UO22+ and HCO3 is higher than that of UO22+ alone, indicating that HCO3 may complex with uranium [26, 27]. Fig. S8b (Supporting information) shows the speciation of U(Ⅵ) in the presence of bicarbonate. In alkaline conditions, HCO3 could easily bind with U(Ⅵ) to form UO2(CO3)22− and UO2(CO3)34−, which may impede the reaction between TPE-A and UO22+ by competing for the reactive sites.

    Figure 3

    Figure 3.  (a) Fluorescence intensity of TPE-A (10 µmol/L) in H2O/THF (85/15, v/v) solution in the presence of different metal ions (10 µmol/L). (b) A competitive binding assay with TPE-A (10 µmol/L) for UO22+ (10 µmol/L) over another metal ion (10 µmol/L). F0: fluorescence intensity of [TPE-A+U]; F: fluorescence intensity of [TPE-A+U+another metal ion].

    To verify the practical application of the sensor, a standard addition method was used to analyze the detection of UO22+ in FuJiang River water samples. The concentration of UO22+ was determined by fluorescence spectrophotometry and ICP-MS. Table S3 (Supporting information) shows that the TPE-A sensor could be used to reliably determine the concentration of UO22+ with satisfactory recoveries (98.7%-104.0%) and relative standard deviation (RSD) values (< 5%). There is good agreement between the TPE-A sensor and ICP-MS measurements. The performance of the proposed sensor was compared with some reported sensors (Table S4 in Supporting information). It was found that TPE-A could detect UO22+ in a relatively wider pH range and established a bigger quenching constant Ksv. More importantly, the detection limit of TPE-A could reach nanomolar level, which could be applied in practical samples in the environment.

    In view of the fluorescence quenching, FTIR analyses were carried out to confirm whether the coordination between TPE-A and UO22+ occurred. Fig. S12 shows the FTIR spectra of TPE-A and U-laden TPE-A, the bands at 1641 and 906 cm−1 in TPE-A are indicative of the –C=N– and =N–O– of amidoxime group, respectively. The adsorption bands at 1641 and 906 cm−1 shift to 1646 and 927 cm−1 after adsorption, respectively, which indicates the coordination of TPE-A with UO22+. The possible fluorescence quenching mechanisms are as follows: (1) after the coordination of TPE-A with UO22+, the aggregates may dissociate, and the solubility of the complex in water may be better, leading to the decrease of fluorescence; (2) the heavy atom effect of UO22+. To determine whether the aggregates dissociated or not after coordination with uranyl ion, particle size analysis using DLS was performed (Fig. 1d). Particles are still observed in the presence of 0.05 equiv. of UO22+ and the particles increase from ca. 137.6 nm to 294.2 nm. The size increase implies that the aggregates of TPE-A do not dissociate after coordination with uranyl ion.

    To further understand the photophysical properties of TPE-A and [TPE-A+UO22+], density functional theory (DFT) calculations were carried out using Gaussian 16 at the level of B3LYP/6-31+G(d), SDD-MWB60. Amidoxime group can coordinate with UO22+ via its electrons of N or O, leading to a strong chelating reaction for uranyl ions. Researchers have proposed several binding motifs [28-30]; while DFT results exhibit that η2 binding motif with the N-O bond is the most stable form, confirmed by single-crystal X-ray diffraction of UO22+ complexes with acetamidoxime and benzamidoxime anions [31]. The possible coordination patterns between the sensor TPE-A and UO22+ were explored, as shown in Fig. S13 (Supporting information). The binding energy of the combination [2TPE-A+UO22+] (−135.92 kcal/mol) is much lower than that of [TPE-A+UO22+] (−109.27 kcal/mol), indicating that two amidoxime groups lean to bind one UO22+. Previous studies have proved that HOMO and LUMO orbitals can describe the sites where molecules tend to lose or gain electrons in the reaction process [32, 33]. The calculated energy levels and HOMO-LUMO energy gaps for the TPE-A and [2TPE-A+UO22+] are illustrated in Fig. 4. The LUMO energy level (−2.0249 eV) in the [2TPE-A+UO22+] is much lower than that of the TPE-A (−1.4582 eV). Before and after TPE-A combines with UO22+, the HOMO-LUMO energy gap decreased from 3.8685 eV to 3.3383 eV. In addition, the combination of TPE-A and UO22+ seems to have strong influence on the HOMO and LUMO properties of the complexes. In the free TPE-A, the electron density of HOMO mainly locates on the TPE and amidoxime moieties and the LUMO mainly distributes on the TPE moiety. When UO22+ is coordinated to the TPE-A ligand, the electrons density on the HOMO of [2TPE-A+UO22+] mainly locates on the TPE and amidoxime moieties, while the LUMO mainly disperses on the UO22+ moiety. Thus, the intramolecular charge transfer from TPE-A to UO22+ is allowed, leading to the fluorescence quenching. These results indicate that the fluorescence quenching after the addition of UO22+ is mainly due to the heavy atom effect of UO22+.

    Figure 4

    Figure 4.  Molecular orbitals of the free TPE-A ligand and [2TPE-A+ UO22+].

    In summary, a simple and sensitive fluorescence AIE-active sensor TPE-A has been successfully designed and synthesized for rapid uranyl ion detection in aqueous solutions. The fluorescence property of TPE-A and its application were investigated. The proposed sensor is effective with a limit of detection as low as 4.7 × 10−9 mol/L at pH 4.0-7.0. This sensor showed good accuracy in the determination of UO22+ concentrations in river water and may have potential applications for the detection of trace UO22+ in environmental systems.

    The authors declare no financial interests/personal relationships which may be considered as potential competing interests.

    We appreciate the financial support received from the National Natural Science Foundation of China (No. 21702193) and China Academy of Engineering Physics (Nos. TP03201601, TP02201711 and JMJJ20190101).

    Supplementary material associated with this article can be found, in the online version, at doi:10.1016/j.cclet.2022.08.005.


    1. [1]

      A. Bleise, P.R. Danesi, W. Burkart, J. Environ. Radioact. 64 (2003) 93–112. doi: 10.1016/S0265-931X(02)00041-3

    2. [2]

      J. Nriagu, D.H. Nam, T.A. Ayanwola, et al., Sci. Total Environ. 414 (2012) 722–726. doi: 10.1016/j.scitotenv.2011.11.037

    3. [3]

      E.S. Craft, A.W. Abu-Qare, M.M. Flaherty, et al., J. Toxicol. Environ. Health Part B 7 (2004) 297–317. doi: 10.1080/10937400490452714

    4. [4]

      M. Yazzie, S.L. Gamble, E.R. Civitello, D.M. Stearns, Chem. Res. Toxicol. 16 (2003) 524–530. doi: 10.1021/tx025685q

    5. [5]

      H. Windom, R. Smith, F. Niencheski, C. Alexander, Mar. Chem. 68 (2000) 307–321. doi: 10.1016/S0304-4203(99)00086-9

    6. [6]

      O. Prat, T. Vercouter, E. Ansoborlo, et al., Environ. Sci. Technol. 43 (2009) 3941–3946. doi: 10.1021/es803658e

    7. [7]

      F. Endrizzi, L.F. Rao, Chem. Eur. J. 20 (2014) 14499–14506. doi: 10.1002/chem.201403262

    8. [8]

      C. Möser, R. Kautenburger, H.P. Beck, Electrophoresis 33 (2012) 1482–1487. doi: 10.1002/elps.201100652

    9. [9]

      M. Krishnakumar, G. Chakrapani, K. Satyanarayana, K. Mukkanti, J. Radioanal. Nucl. Chem. 307 (2016) 497–505. doi: 10.1007/s10967-015-4147-9

    10. [10]

      M.R. Jamali, Y. Assadi, F. Shemirani, et al., Anal. Chim. Acta 579 (2006) 68–73. doi: 10.1016/j.aca.2006.07.006

    11. [11]

      S.F. Wang, S.L. Yang, H.X. Wu, et al., Sci. Bull. 64 (2019) 315–320. doi: 10.1016/j.scib.2019.01.025

    12. [12]

      C.Y. Wang, C.C. Wang, X.W. Zhang, et al., Chin. Chem. Lett. 33 (2022) 1353–1357. doi: 10.1016/j.cclet.2021.08.095

    13. [13]

      J.Q. Ma, W.W. He, X.L. Han, D.B. Hua, Talanta 168 (2017) 10–15. doi: 10.1016/j.talanta.2017.02.058

    14. [14]

      A.A. Elabd, M.S. Attia, J. Lumin. 165 (2015) 179–184. doi: 10.1016/j.jlumin.2015.04.024

    15. [15]

      S. Zhang, J.M. Yan, A.J. Qin, et al., Chin. Chem. Lett. 24 (2013) 668–672. doi: 10.1016/j.cclet.2013.05.014

    16. [16]

      B. Liu, Y.H. Tan, Q.H. Hu, et al., Sens. Actuators B: Chem. 296 (2019) 126675. doi: 10.1016/j.snb.2019.126675

    17. [17]

      J. Zhang, Q. Zang, F. Yang, et al., J. Am. Chem. Soc. 143 (2021) 3944–3950. doi: 10.1021/jacs.1c00243

    18. [18]

      J. Wen, Z. Huang, S. Hu, et al., J. Hazard. Mater. 318 (2016) 363–370. doi: 10.1016/j.jhazmat.2016.07.004

    19. [19]

      N. Lin, W.S. Ren, J.N. Hu, et al., Dyes Pigments 166 (2019) 182–188. doi: 10.1016/j.dyepig.2019.02.048

    20. [20]

      M.R. Palmer, J.M. Edmond, Geochim. Cosmochim. Acta 57 (1993) 4947–4955. doi: 10.1016/0016-7037(93)90131-F

    21. [21]

      C.W. Abney, R.T. Mayes, T. Saito, et al., Chem. Rev. 117 (2017) 13935–14013. doi: 10.1021/acs.chemrev.7b00355

    22. [22]

      Y. Yuan, S. Zhao, J. Wen, et al., Adv. Funct. Mater. 29 (2019) 1805380. doi: 10.1002/adfm.201805380

    23. [23]

      H. Zhang, J. Liu, L. Du, et al., Mater. Chem. Front. 3 (2019) 1143–1150. doi: 10.1039/C9QM00156E

    24. [24]

      J. Mei, N.L.C. Leung, R.T.K. Kwok, et al., Chem. Rev. 115 (2015) 11718–11940. doi: 10.1021/acs.chemrev.5b00263

    25. [25]

      H. Tong, Y.Q. Dong, M. Haübler, et al., Chem. Commun. 2006 (2006) 1133–1135.

    26. [26]

      J. Duan, H. Ji, X. Zhao, et al., Chem. Eng. J. 393 (2020) 124692. doi: 10.1016/j.cej.2020.124692

    27. [27]

      J. Duan, H. Ji, T. Xu, et al., Chem. Eng. J. 406 (2021) 126752. doi: 10.1016/j.cej.2020.126752

    28. [28]

      A.Y. Zhang, T. Asakura, G. Uchiyama, React. Funct. Polym. 57 (2003) 67–76. doi: 10.1016/j.reactfunctpolym.2003.07.005

    29. [29]

      G.X. Tian, S.J. Teat, Z.Y. Zhang, L.F. Rao, Dalton Trans. 41 (2012) 11579–11586. doi: 10.1039/c2dt30978e

    30. [30]

      J.L. Wang, S.T. Zhuang, Rev. Environ. Sci. Bio/Technol. 18 (2019) 437–452. doi: 10.1007/s11157-019-09507-y

    31. [31]

      S. Vukovic, L.A. Watson, S.O. Kang, et al., Inorg. Chem. 51 (2012) 3855–3859. doi: 10.1021/ic300062s

    32. [32]

      X.H. Yi, H. Ji, C.C. Wang, et al., Appl. Catal. B: Environ. 293 (2021) 120229. doi: 10.1016/j.apcatb.2021.120229

    33. [33]

      C. Zhao, J. Wang, X. Chen, et al., Sci. Total Environ. 752 (2021) 141901. doi: 10.1016/j.scitotenv.2020.141901

  • Figure 1  (a) Fluorescence spectra of TPE-A (10 µmol/L) in H2O/THF mixtures with fw ranging from 0% to 100%. Dynamic light scattering results of (b) TPE-A (10 µmol/L) in H2O/THF (90/10, v/v) mixture, (c) TPE-A (10 µmol/L) in H2O/THF (85/15, v/v) mixture, and (d) TPE-A (10 µmol/L) with UO22+ (0.5 µmol/L) in the H2O/THF (85/15, v/v) mixture.

    Figure 2  (a) Fluorescence intensity of TPE-A (10 µmol/L) and TPE-A (10 µmol/L) + UO22+ (0.5 µmol/L) at 444 nm in H2O/THF (85/15, v/v) solution at different pH. (b) The response time curve of TPE-A (10 µmol/L) to uranyl ions (0.5 µmol/L) at 444 nm in H2O/THF (85/15, v/v) mixture at pH 7.0. (c) Fluorescence spectra of TPE-A (10 µmol/L) in the presence of different concentrations (0-0.5 µmol/L) in the H2O/THF (85/15, v/v) solution at pH 7.0. (d) The linear plot and relationship of (F0-F)/F0 versus the concentrations of UO22+ (0.05-0.45 µmol/L).

    Figure 3  (a) Fluorescence intensity of TPE-A (10 µmol/L) in H2O/THF (85/15, v/v) solution in the presence of different metal ions (10 µmol/L). (b) A competitive binding assay with TPE-A (10 µmol/L) for UO22+ (10 µmol/L) over another metal ion (10 µmol/L). F0: fluorescence intensity of [TPE-A+U]; F: fluorescence intensity of [TPE-A+U+another metal ion].

    Figure 4  Molecular orbitals of the free TPE-A ligand and [2TPE-A+ UO22+].

  • 加载中
计量
  • PDF下载量:  6
  • 文章访问数:  988
  • HTML全文浏览量:  186
文章相关
  • 发布日期:  2023-04-15
  • 收稿日期:  2022-04-05
  • 接受日期:  2022-08-03
  • 修回日期:  2022-07-16
  • 网络出版日期:  2022-08-05
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

/

返回文章