引用本文:
Mohammad Mazloum-Ardakani, Hossein Rajabi, Hadi Beitollahi. Homogeneous and nanomolar detection of hydrazine by indigocarmine as a mediator at the surface of TiO2 nanoparticles modified carbon paste electrode[J]. Chinese Chemical Letters,
2012, 23(2): 213-216.
doi:
10.1016/j.cclet.2011.10.016
Citation: Mohammad Mazloum-Ardakani, Hossein Rajabi, Hadi Beitollahi. Homogeneous and nanomolar detection of hydrazine by indigocarmine as a mediator at the surface of TiO2 nanoparticles modified carbon paste electrode[J]. Chinese Chemical Letters, 2012, 23(2): 213-216. doi: 10.1016/j.cclet.2011.10.016

Citation: Mohammad Mazloum-Ardakani, Hossein Rajabi, Hadi Beitollahi. Homogeneous and nanomolar detection of hydrazine by indigocarmine as a mediator at the surface of TiO2 nanoparticles modified carbon paste electrode[J]. Chinese Chemical Letters, 2012, 23(2): 213-216. doi: 10.1016/j.cclet.2011.10.016

Homogeneous and nanomolar detection of hydrazine by indigocarmine as a mediator at the surface of TiO2 nanoparticles modified carbon paste electrode
摘要:
The homogeneous electrocatalytic oxidation of hydrazine (HZ) has been studied by indigocarmine (IND) as a mediator at the surface of TiO2 nanoparticles modified carbon paste electrode (TNMCPE). Cyclic voltammetry was used to study the electrochemical behavior of IND at different scan rates. The voltammetric response of the modified electrode was linear against the concentration of HZ in the ranges of 3.0×10-8 mol/L-7.0×10-6 mol/L with differential pulse voltammetry method. The detection limit (3σ) was determined as 27.3 nmol/L. To evaluate the applicability of the proposed method to real samples, the modified CPE was applied to the determination of HZ in water samples.
English
Homogeneous and nanomolar detection of hydrazine by indigocarmine as a mediator at the surface of TiO2 nanoparticles modified carbon paste electrode
Abstract:
The homogeneous electrocatalytic oxidation of hydrazine (HZ) has been studied by indigocarmine (IND) as a mediator at the surface of TiO2 nanoparticles modified carbon paste electrode (TNMCPE). Cyclic voltammetry was used to study the electrochemical behavior of IND at different scan rates. The voltammetric response of the modified electrode was linear against the concentration of HZ in the ranges of 3.0×10-8 mol/L-7.0×10-6 mol/L with differential pulse voltammetry method. The detection limit (3σ) was determined as 27.3 nmol/L. To evaluate the applicability of the proposed method to real samples, the modified CPE was applied to the determination of HZ in water samples.

计量
- PDF下载量: 0
- 文章访问数: 841
- HTML全文浏览量: 5