A New Conductivity Detector for Capillary Electrophoresis

Zuan Guang CHEN Jin Yuan MO Tian Yao XIE Li Shi WANG Xiao Yun YANG Kong ZHANG Min Sheng ZHANG

引用本文: Zuan Guang CHEN,  Jin Yuan MO,  Tian Yao XIE,  Li Shi WANG,  Xiao Yun YANG,  Kong ZHANG,  Min Sheng ZHANG. A New Conductivity Detector for Capillary Electrophoresis[J]. Chinese Chemical Letters, 2000, 11(5): 439-442. shu
Citation:  Zuan Guang CHEN,  Jin Yuan MO,  Tian Yao XIE,  Li Shi WANG,  Xiao Yun YANG,  Kong ZHANG,  Min Sheng ZHANG. A New Conductivity Detector for Capillary Electrophoresis[J]. Chinese Chemical Letters, 2000, 11(5): 439-442. shu

A New Conductivity Detector for Capillary Electrophoresis

  • 基金项目:

    This research was supported partially by the National Natural Science Foundation of China (Grant No.29675033). We also thank engineer Hexian SITU for his help.

摘要: A new conductivity detector for capillary electrophoresis consisting of an electrochemical cell and a conductive meter was developed. In the cell, the microelectrode and capillary were inserted through the cell wall and fixed by screws and sealing ring, the ends of microelectrode and capillary were located by a guide with two cross holes. LOD for K+ was 1.5×10-5 mol/L.