引用本文:
Zhi Hua WANG, Min CAI, Shu Jun WANG. Determination of Iron in Layered Crystal Sodium Disilicate and Sodium Silicate by Flame Atomic Absorption Spectrometry with Boric Acid as a Matrix Modifier[J]. Chinese Chemical Letters,
2006, 17(6): 809-812.
Citation: Zhi Hua WANG, Min CAI, Shu Jun WANG. Determination of Iron in Layered Crystal Sodium Disilicate and Sodium Silicate by Flame Atomic Absorption Spectrometry with Boric Acid as a Matrix Modifier[J]. Chinese Chemical Letters, 2006, 17(6): 809-812.
Citation: Zhi Hua WANG, Min CAI, Shu Jun WANG. Determination of Iron in Layered Crystal Sodium Disilicate and Sodium Silicate by Flame Atomic Absorption Spectrometry with Boric Acid as a Matrix Modifier[J]. Chinese Chemical Letters, 2006, 17(6): 809-812.
Determination of Iron in Layered Crystal Sodium Disilicate and Sodium Silicate by Flame Atomic Absorption Spectrometry with Boric Acid as a Matrix Modifier
摘要:
The effects of matrix silicate and experimental conditions on the determination of iron in flame atomic absorption spectrometry (FAAS) were investigated. It was found that boric acid as a matrix modifier obviously eliminated silicate interference. Under the optimum operating conditions, the determination results of iron in layered crystal sodium disilicate and sodium silicate samples by FAAS were satisfactory. The linear range of calibration curve is 0-10.5μg.mL-1, the relative standard deviation of method is 1.2%-2.2%, the recovery of added iron is 96.0%-101%, thesensitivity is 0.19μg·mL-1, and deyection limit is 77 ng·mL-1, The effect of the determination of iron of the standard curve method, standard addition calibration and colorimetry method was the same, but the first has the merits of rapid sample preparation, reduced contamination risks and fast analysis.
English
Determination of Iron in Layered Crystal Sodium Disilicate and Sodium Silicate by Flame Atomic Absorption Spectrometry with Boric Acid as a Matrix Modifier
Abstract:
The effects of matrix silicate and experimental conditions on the determination of iron in flame atomic absorption spectrometry (FAAS) were investigated. It was found that boric acid as a matrix modifier obviously eliminated silicate interference. Under the optimum operating conditions, the determination results of iron in layered crystal sodium disilicate and sodium silicate samples by FAAS were satisfactory. The linear range of calibration curve is 0-10.5μg.mL-1, the relative standard deviation of method is 1.2%-2.2%, the recovery of added iron is 96.0%-101%, thesensitivity is 0.19μg·mL-1, and deyection limit is 77 ng·mL-1, The effect of the determination of iron of the standard curve method, standard addition calibration and colorimetry method was the same, but the first has the merits of rapid sample preparation, reduced contamination risks and fast analysis.
扫一扫看文章
计量
- PDF下载量: 0
- 文章访问数: 0
- HTML全文浏览量: 0

下载: